The Tiger Select is a revolutionary hand-held gas detector for the rapid, accurate detection of benzene and Total Aromatic Compounds (TACs).
The instrument’s rugged body can withstand harsh environments |
When fully charged, the lithium-ion battery can last up the 24 hours |
Protection against a range of conditions and weather temperatures |
Fast Response Time & Clear Down |
Description
Utilising the high output ION Science 10.0 eV lamp, the Tiger XT Select (XTS) portable benzene gas detector is capable of detecting Total Aromatic Compounds (TACs) including Benzene, Toluene and Acetone. The instrument is supplied with a pack of benzene pre-filter tubes to detect benzene selectively. The tube can be easily attached to ensure rapid detection and selective measurement of benzene. Throughout the measurement process, Tiger XT Select benzene gas detector continuously displays real time data. Tiger XT Select can also provide 15 minute short term exposure limits (STELs) and 8 hour time weighted averages (TWAs) for Total Aromatic Compounds (TACs).
The Tiger XT Select handheld benzene gas detector can be used in standard operational mode without the use of a benzene pre-filter tube to deliver active indications of volatile organic compounds (VOCs).
Features
Improved Robust Design
The instrument’s rugged body can withstand harsh environments
Long Rechargeable Battery Life
When fully charged, the lithium-ion battery can last up the 24 hours
IP65 Ingress Protection
Protection against a range of conditions and weather temperatures
Fast Response Time & Clear Down
<2 second response time, one of the fastest and most accurate on the market
Specifications
Resolution PPM model |
0.001 ppm (1 ppb) benzene in Tube mode 0.01 ppm in TAC mode 0.1 ppm in standard running mode: |
Resolution PPB model |
0.001 ppm (1 ppb) benzene in Tube mode. 0.001 ppm in TAC modes. 0.001 ppm in standard running mode |
Maximum Reading |
0 to 200 ppm benzene in tube mode, up to 20,000 ppm in TAC mode (gas dependent) |
Response Time |
T90 < 2 seconds in normal running and TAC mode |
Accuracy |
± 10% display reading ± one digit benzene |
Linearity |
± 5% display reading ± one digit |
Response Time |
120 seconds in Tube mode. Progressive indication of benzene breakthrough is displayed in real time |
Intrinsically Safe Approvals |
II1GExiaIICT4Ga |
Battery Life |
Li-ion: life up to 24 hours, charge time 6.5 hours |
PID Lamps |
10.0eV Krypton PID lamp |
Data Logging |
> 120,000 data log points including date and time stamp |
Communication |
Direct USB 1.1 |
Calibration |
2 and 3 point calibration (via calibration kit accessory) |
Alarm |
Flashing LED’s Amber (low alarm) Red (high alarm) Sounder 95 dBA at 300mm (12”) Vibration on alarm. Pre-programmed TWA and STEL* |
Flow Rate |
>220 ml/min (150 cc/min flow alarm) |
Temperature |
Operating: -20 to 60 0C, -4 to 140 0F (non Intrinsically Safe) |
Protection |
Designed to IP65 (heavy rain) |
Weight & Dimensions |
Instrument (probe fitted,no tube attached) Length:465xHeight:89xDepth:61 mm (18.3×3.5×2.4”) Standardcase Packed weight: 5kg (176oz) |
*Model and gas dependent.
**Maximum reading is achieved with certain analytes such as ethanol.
***All specifications quoted are at calibration point and under the same ambient conditions.
Specifications are based on Benzene calibrations at 20 °C and 1000mBar
Tiger XT Select V1.0 This publication is not intended to form the basis of a contract and specifications can change without notice.