TIGER  XT SELECT Handheld Benzene Gas Detector

TIGER  XT SELECT Handheld Benzene Gas Detector

Description

The Tiger Select is a revolutionary hand-held gas detector for the rapid, accurate detection of benzene and Total Aromatic Compounds (TACs).

Features
The instrument’s rugged body can withstand harsh environments
When fully charged, the lithium-ion battery can last up the 24 hours
Protection against a range of conditions and weather temperatures
Fast Response Time & Clear Down

Description

Utilising the high output ION Science 10.0 eV lamp, the Tiger XT Select (XTS) portable benzene gas detector is capable of detecting Total Aromatic Compounds (TACs) including Benzene, Toluene and Acetone. The instrument is supplied with a pack of benzene pre-filter tubes to detect benzene selectively. The tube can be easily attached to ensure rapid detection and selective measurement of benzene. Throughout the measurement process, Tiger XT Select benzene gas detector continuously displays real time data. Tiger XT Select can also provide 15 minute short term exposure limits (STELs) and 8 hour time weighted averages (TWAs) for Total Aromatic Compounds (TACs).

The Tiger XT Select handheld benzene gas detector can be used in standard operational mode without the use of a benzene pre-filter tube to deliver active indications of volatile organic compounds (VOCs).

 

 

Features

 

  • Improved Robust Design
    The instrument’s rugged body can withstand harsh environments

  • Long Rechargeable Battery Life
    When fully charged, the lithium-ion battery can last up the 24 hours

  • IP65 Ingress Protection
    Protection against a range of conditions and weather temperatures

  • Fast Response Time & Clear Down
    <2 second response time, one of the fastest and most accurate on the market

  • Instantaneous Alarms
        Bright visible alarms: RED & AMBER with loud sounder (95 dBA at 300 mm (12”))
  • Humidity Resistant and Anti-Contamination Design
        Patented Fence Electrode Technology ensures optimal performance and extends run time

 

 

Specifications

 

Resolution PPM model

0.001 ppm (1 ppb) benzene in Tube mode     0.01 ppm in TAC mode    0.1 ppm in standard running mode:

Resolution PPB model

0.001 ppm (1 ppb) benzene in Tube mode.    0.001 ppm in TAC modes.    0.001 ppm in standard running mode

Maximum Reading

0 to 200 ppm benzene in tube mode, up to 20,000 ppm in TAC mode (gas dependent)

Response Time

T90 < 2 seconds in normal running and TAC mode

Accuracy

± 10% display reading ± one digit benzene

Linearity

± 5% display reading ± one digit

Response Time

120 seconds in Tube mode. Progressive indication of benzene breakthrough is displayed in real time

Intrinsically Safe Approvals

II1GExiaIICT4Ga
Tamb = – 15 0C ≤Ta ≤+45 0C (with alkaline battery pack) ITS09ATEX26890X IECEx ITS 10.0036X
3193491 conforms to UL Std. 913, 61010-1 &
Certified to CAN/CSA Std. C22.2 No. 61010-1

Battery Life

Li-ion: life up to 24 hours, charge time 6.5 hours
Alkaline: 3 x AA, typically 8.5 hours life

PID Lamps

10.0eV Krypton PID lamp

Data Logging

> 120,000 data log points including date and time stamp

Communication

Direct USB 1.1

Calibration

2 and 3 point calibration (via calibration kit accessory)

Alarm

Flashing LED’s Amber (low alarm) Red (high alarm) Sounder 95 dBA at 300mm (12”) Vibration on alarm. Pre-programmed TWA and STEL*

Flow Rate

>220 ml/min (150 cc/min flow alarm)

Temperature

Operating: -20 to 60 0C, -4 to 140 0F (non Intrinsically Safe)
Humidity: 0-99% RH (non condensing)

Protection

Designed to IP65 (heavy rain)
1180
EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A

Weight & Dimensions

Instrument (probe fitted,no tube attached) Length:465xHeight:89xDepth:61 mm (18.3×3.5×2.4”) Standardcase Packed weight: 5kg (176oz)

 

*Model and gas dependent.
**Maximum reading is achieved with certain analytes such as ethanol.
***All specifications quoted are at calibration point and under the same ambient conditions.
Specifications are based on Benzene calibrations at 20 °C and 1000mBar
Tiger XT Select V1.0 This publication is not intended to form the basis of a contract and specifications can change without notice.