The Tiger VOC detector is a revolutionary handheld gas detection instrument for the rapid, accurate detection of volatile organic compounds (VOCs) within the harshest of environments.
Improved Robust Design |
Large Internal Gas Table |
IP65 Ingress Protection |
Fast Response Time & Clear Down |
Description
The Tiger XT’s photoionisation detection (PID) technology has been independently verified as best performing on the market for speed, accuracy, resistance to humidity and contamination, thanks to its patented Fence Electrode Technology. Its patented Fence Electrode Technology and anti-contamination design ensures optimal performance within humid and heavily contaminated atmospheres, extending run time in the field.
The Tiger XT is the most advanced handheld VOC detector on the market with the widest measurement range, accurately detecting gases down to 1 part per billion (ppb) up to 20,000 part per million (ppm). Tiger has the fastest response time on the market of just two seconds, and is as quick to clear down. The Tiger XT handheld VOC gas detector can detect over 750 VOCs and toxic compounds!
Features
Improved Robust Design
The instrument’s rugged body can withstand harsh environments
Large Internal Gas Table
Internal gas table has over 750 VOCs & toxic compounds
IP65 Ingress Protection
Protection against a range of conditions and weather temperatures
Fast Response Time & Clear Down
<2 second response time, one of the fastest and most accurate on the market
Instantaneous Alarms
Bright visible alarms: RED & AMBER with loud sounder (95 dBA at 300 mm (12”))
Specifications
Minimum Resolution* |
1 ppb or 0.001 mg/m3 |
Maximum Reading** |
20,000 ppm or 20,000 mg/m3 |
Response Time |
T90 < 2 seconds |
Accuracy* |
± 5% display reading ± one digit |
Linearity* |
± 5% display reading ± one digit |
Intrinsically Safe Approvals |
II1GExiaIICT4Ga |
Battery Life |
Li-ion: life up to 24 hours continual use |
Lamps |
10.6 eV Krypton PID lamp (standard) and 11.7eV lamps available |
Data Logging* |
Including date / time: 120,000 points |
Communication |
Direct USB 1.1 connection |
Calibration |
Standard calibration 100 ppm isobutylene Custom calibration capability |
Alarm |
Flashing LED and 95 dBA at 300mm (12”) audible sounder Selectable vibrating alarm |
Flow Rate |
220 ml/min in ambient conditions (with blocked flow alarm) |
Temperature |
Operating: -20 to 60 0C, -4 to 140 0F (non Intrinsically Safe) |
Protection |
Designed to IP65 (heavy rain) |
Weight & Dimensions |
Instrument without probe Width: 340 x Height: 90 x Depth: 60 mm (13.4 x 3.6 x 2.4”) Standard case 420 x 320 x 97 mm (16.5 x 12.5 x 3.8”) Instrument weight 0.72 kg (1.56lb) Packed weight: 5 .5kg (12lb) |
Standard case |
420x320x97mm(16.5×12.5×3.8”) Instrument weight 0.72 kg (1.56lb) Packed weight: 5 .5kg (12lb) |
*Model and gas dependent.
**Maximum reading is achieved with certain analytes such as ethanol.
***Specifications are based on isobutylene calibrations at 20 °C and 1000mBar.
All specifications quoted are at calibration point and under the same ambient conditions.
**** Based on continuous running.
#For indicative measurement only. Quoted accuracy achievable up to 2,000 ppm. For more accurate detection, calibration around concentration of interest is recommended.
Tiger XT V1.0. This publication is not intended to form the basis of a contract and specifications can change without notice.